Siemens Amira 1.5T BioMatrix
Amira 1.5T Manufactured 2019 Aalborg Warehouse
Product Overview
Siemens Amira 1.5 T MRI system manufactured in 2019, serial number 174102, with a 16-channel configuration and XF gradient type.
The system is equipped with an AX93 magnet, model 10835951, manufactured in 2019. The recorded helium level is 375 liters, magnet pressure is 15.3 psiA and shield temperature is 49.3 K.
The system features a Sumitomo F-70H compressor manufactured in 2019 and an RDK-408L3 cold head manufactured in 2019. The main workstation is a Z440 - 11062060 running software version VA12S.
Positioning pads, software discs and system operator manuals are included. The system was recorded as functional following preventive maintenance and QA performed on 03 March 2026.
System QA recorded 37 passed.
Full Specifications
| Manufacturer | Siemens |
|---|---|
| Model | Amira 1.5T |
| Type | MRI System |
| Year | 2019 |
| Serial Ref. | NVI-C00547 |
| Condition | Excellent |
| Availability | In Stock |
| Location | Aalborg Warehouse |
| Field Strength | 1.5T |
|---|---|
| Magnet Model | 10835951 |
| Magnet YOM | 2019 |
| Bore Size | 60 cm |
| Helium Level | 375 liters 40% |
| Gradient Type | XF |
|---|---|
| Gradient Strength | 33 mT/m 125T/m/s |
| RF Channels | 16 |
| Compressor Type | Sumitomo F-70H |
|---|---|
| Compressor YOM | 2019 |
| Coldhead Type | RDK-408L3 |
| Console Model | Z440 – 11062060 |
|---|---|
| Software | VA12S |
| Options | |
| Coils | |
| Notes | Siemens Amira 1.5 T MRI system manufactured in 2019, serial number 174102. The system has a 16-channel configuration, an XF gradient type, and an AX93 magnet. The system has not been upgraded and has recorded zero quenches. Magnet model number 10835951, serial number 932181, manufactured in 2019. Current helium level is 375 litres, magnet pressure is 15.3 psiA and shield temperature is 49.3 K. The Sumitomo F-70H compressor was manufactured in 2019, serial number SC319385K, with 48,924 recorded running hours and a pressure level of 21 Bar. The RDK-408L3 cold head was manufactured in 2019 and has a recorded temperature of 4 K. The main workstation is Z440-11062060, serial number 1537, running software version VA12S. Positioning pads, software discs and system operator manuals are included. Extra trolley and base plate are not included. The system logbook is not present. Preventive maintenance and QA were performed on 03 March 2026. The system was recorded as functional. System QA recorded 37 passed tests and one N/A result. |
|---|
| Installation Support | Available on request |
|---|---|
| System Inspection | Completed |
| Export Packing & Shipping | Managed by our team |
| After-Sales Support | Ongoing support available |
| Parts Support | 14,000+ parts in stock |
From NOVO Imaging to Clinical Use
NOVO Imaging Used vs. Brand New
| Aspect | NOVO Imaging Used | Brand New OEM |
|---|---|---|
| Price | Quotation required | Request OEM quotation |
| Lead Time | Dispatch to be confirmed | 6 – 18 months |
| Clinical Performance | Inspection evidence where available | Latest generation |
| Inspection Report | QA records, where available | Factory spec sheet |
| Spare Parts Availability | 14,000+ in stock | OEM lead times apply |
| Installation Support | Service by written agreement | OEM team |
| Trade-In | Subject to evaluation | Ask OEM |