SiemensMAGNETOM Amira 1.5T BioMatrix
Amira Manufactured 2019 Pending, Hospital
Product Overview
Available Siemens MAGNETOM Amira 1.5T BioMatrix MRI system manufactured in 2019.
This system incorporates Siemens BioMatrix technology and features a 16-channel configuration, XF gradient platform, AX93 magnet and a Siemens Z440 main workstation running software version VA12S.
The configuration includes BioMatrix and dedicated RF coils, positioning pads, software discs, system operator manuals and QA phantoms.
Preventive maintenance and quality assurance testing were completed on 3 March 2026. The system was recorded as functional, with 37 main system QA tests passed and one test marked as not applicable.
Five RF coils passed their individual QA tests. Three coils recorded failed results: two Body 13 BioMatrix coils and one Ultra Flex Small 18 coil.
Please contact NOVO Imaging for the complete configuration, pricing, availability and delivery information.
Full Specifications
| Manufacturer | Siemens |
| Model | Amira |
| Type | MRI System |
| Year | 2019 |
| Serial Ref. | NVI-C00547 |
| Condition | Excellent |
| Availability | Incoming |
| Location | Pending, Hospital |
| Field Strength | 1.5T |
| Magnet Model | 10835951 |
| Magnet YOM | 2019 |
| Bore Size | 60 cm |
| Helium Level | 45% |
| Gradient Type | XF |
| Gradient Strength | 125T/m/s 125T/m/s |
| RF Channels | 16 |
| Compressor Type | Sumitomo F-70H |
| Compressor YOM | 2019 |
| Coldhead Type | RDK-408L3 |
| Console Model | Z440 – 11062060 |
| Software | VA12S |
| Options | |
| Coils | |
| Notes | Siemens MAGNETOM Amira 1.5T BioMatrix MRI system manufactured in 2019. System serial number 174102. The system incorporates Siemens BioMatrix technology and has a 16-channel configuration, XF gradients and an AX93 magnet. It has not been upgraded and has recorded zero quenches. The current helium quantity is 375 litres. Magnet pressure is 15.3 psiA and the recorded shield temperature is 49.3 K. The Sumitomo F-70H compressor was manufactured in 2019 and has a recorded running time of 48,924 hours. The RDK-408L3 cold head was manufactured in 2019 and has a recorded operating temperature of 4 K. Preventive maintenance and QA were completed on 3 March 2026. The system was recorded as functional. The main system QA recorded 37 passed tests and one test marked as not applicable. Positioning pads, software discs and system operator manuals are included. An extra trolley and base plate are not included. The system logbook is not present. Five coils passed individual QA testing. Two Body 13 BioMatrix coils and the Ultra Flex Small 18 coil recorded failed QA results. |
| Installation Support | Available on request |
| System Inspection | Completed |
| Export Packing & Shipping | Managed by our team |
| After-Sales Support | Ongoing support available |
| Parts Support | 14,000+ parts in stock |
From NOVO Imaging to Clinical Use
NOVO Imaging Used vs. Brand New
| Aspect | NOVO Imaging Used | Brand New OEM |
|---|---|---|
| Typical Price Range | €50k – €490k | €500k – €2.0M |
| Lead Time | In Stock — No Wait | 6 – 18 months |
| Clinical Performance | Verified & tested | Latest generation |
| Inspection Report | 120-point QA included | Factory spec sheet |
| Spare Parts Availability | 14K+ in stock | OEM lead times apply |
| Installation Support | NOVO Imaging engineers worldwide | OEM team |
| Trade-In Accepted | Yes | Rarely |